Set up your own cloud-native simulation in minutes.Start Simulating Now

1 boundary layer vs 3 layers HEX mesh Test at strict yPlus20-175

Open Project
Copy Project
1 boundary layer vs 3 layers HEX mesh Test at strict yPlus20-175 image
views 409shares 2
DaleKramer
Created

Last modified

Statistics
geometries 2 Geometriesmeshes 8 Meshessimulations 5 Simulation setupsruns 11 Results

About this project

To determine how much difference in results values will be seen if 1 boundary layer is used instead of the more accepted practice of 3 layers for a CFD HEX mesh (with unattached flow) within a very strict yPlus wall function range of 20-175 using the kW_SST turbulence model. The meshes have about 99 percent of the geometry surface area within yPlus20-175.

Share this project

Related Projects

airflow_around_a_spoiler_1 image
Tutorial - Airflow around a spoiler

by Ali_ArafatAli_Arafat


Project History

  • dschroeder

    dschroeder created this project

  • DaleKramer

    DaleKramer copied this project